Sewer: Frequently Asked Questions


How does the performance in service of plastic pipe systems compare with other sewer pipe materials?
Does diametric deflection of flexible pipes affect leak tightness?
Does angular deflection at joints affect leak tightness?
Are plastic pipe systems interchangeable?
Are there EN standards for all plastic sewer pipe systems?
Is the performance of structured wall sewer pipes as good as solid wall pipes?
Does pipe stiffness greatly affect the level of deflection?
Can plastic sewer pipes be laid with a similar cover to clay and concrete pipes?
How deep can plastic sewer pipes be buried?
How can I calculate the likely level of deflection?
How does deflection of flexible pipes affect flow capacity?
Is abrasion a problem with plastic sewer pipes?
How does the type of backfill material affect the performance of a plastic sewer pipe?
What are the important factors when installing plastic sewer pipes?
Can off-cuts and recovered pipes be recycled?
What is the recommended minimum depth of cover for plastic sewer pipes?
What jetting pressures should be used on plastic sewer pipes?
Is deflection of plastic sewer pipes visible on CCTV?



How does the performance in service of plastic pipe systems compare with other sewer pipe materials?

Plastic sewer pipes have one fifth of the number of defects compared with rigid sewer pipes.

Read more ...

Return to Top


Does diametric deflection of flexible pipes affect leak tightness?

It has been proven that joints on plastic sewer pipes with up to 10% deflection retain leak tightness.

Read more ...

Return to Top


Does angular deflection at joints affect leak tightness?

It has been proven that joints with up to 2 degrees deflection retain leak tightness.

Read more ...

Return to Top


Are plastic pipe systems interchangeable?

All smooth wall pipes are interchangeable. Pipes with external profiles may require adaptors to connect to other types of pipe.

Read more ...

Return to Top


Are there EN standards for all plastic sewer pipe systems?

Yes - all types of plastic sewer pipes are now covered by EN Standards.

Read more ...

Return to Top


Is the performance of structured wall sewer pipes as good as solid wall pipes?

Yes - Structured wall pipes and solid wall pipes meet the same basic performance requirements.

Read more ...

Return to Top


Does pipe stiffness greatly affect the level of deflection?

The pipe stiffness has only limited effect provided the level of compaction of the surrounding soil is good.

Read more ...

Return to Top


Can plastic sewer pipes be laid with a similar cover to clay and concrete pipes?

Yes - Plastic pipes can be buried with similar minimum cover to traditional pipe materials.

Read more ...

Return to Top


How deep can plastic sewer pipes be buried?

With normal installation techniques pipes can be buried up to 6 metres deep.

Read more ...

Return to Top


How can I calculate the likely level of deflection?

Deflection calculations are not normally necessary. A simple graph can be used to predict deflection.

Read more ...

Return to Top


How does deflection of flexible pipes affect flow capacity?

The effect on capacity is negligible. A 10% deflection represents only a 2,5% reduction in full bore capacity.

Read more ...

Return to Top


Is abrasion a problem with plastic sewer pipes?

Abrasion is so limited it has absolutely no affect on the performance of a plastic sewer pipe.

Read more ...

Return to Top


How does the type of backfill material affect the performance of a plastic sewer pipe?

The type of backfill material can influence the extent of deflection of plastic sewer pipes.

Read more ...

Return to Top


What are the important factors when installing plastic sewer pipes?

Good installation practise and workmanship are the most important factors to assure a good performance of the sewer system.

Read more ...

Return to Top


Can off-cuts and recovered pipes be recycled?

Yes - The EN standards explain how and where recycled pipe can be re-used in production of new pipes.

Read more ...

Return to Top


What is the recommended minimum depth of cover for plastic sewer pipes?

Different countries have varying requirements however extensive research with traffic loading on pipes with as little as 800 mm cover has been successfully undertaken.

Read more ...

Return to Top


What jetting pressures should be used on plastic sewer pipes?

A jetting pressure of 120 bar is more than adequate to remove all blockages from plastic sewer pipes.

Read more ...

Return to Top


Is deflection of plastic sewer pipes visible on CCTV?

CCTV can only be used to detect excessive deflection of plastic sewer pipes.

Read more ...

Return to Top
 
  A Sharcq Production © 2008